0.6/1kv XLPE power cables

0.6/1kv XLPE power cable


Keywords:
XLPE Insulated power cable
XLPE armoured power cable
CU/XLPE/SWA PVC power cable

Application scope
The XLPE power cable with rated voltage at is  0.6/1kV will be applied to power, lighting and control system on
shipboard and off shore platform, and it aslo available to metallurgical industry, chemical works, power plant and mining indudtry ect.
Advantage
XLPE power cable has highly resistant to electric strength, mechanical strength, highly anti-ageing, environmental stress resisting and anti-chemical corrosions, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Specification
1.The max. long term permissible operating temperature of cable conductor is 90°C, m degrees in JV type 5 between the 2.
2.When wire core short circuit the highest temperature of cable conductor is no more than J0 bend J0 hour 5D05 territory when van  250°C.
3.The laying environment temperature of cable should be not less than 0°C, the optimum L-Y5 bend in th most Y.
Construction of cable
1.tinner copper conductive cores
2.rubber  insulated
3.wrapping
4.PVC/XLPE/PO inner sheath
5.metal wire braided
6.PVC/XLPE/PO outer sheath

More to visit our webiste:  www.xlpepowercable.com

XLPE Underground Armoured Power Cable

XLPE Underground Armoured Power Cable


Structure for armoured underground power cable

Conductor: Solid or stranded copper
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)
No. Of Core and Sectional Area(mm2) :
1 Core 1.5-800     25-800     25-1200     25-1200     35-1200     50-1200     50-1200     50-1200
2 Core 1.5-185     25-185
3 Core 1.5-400     25-400     25-400     25-400     35-400     50-400     50-400     50-400
4 Core 2.5-400     25-400
5 Core 2.5-400       25-400 


1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502)Also can do by sta
 
ndard of ASTM,BS,DIN and AS/NZS or other standards as request.

 XLPE Underground Armoured Power Cable

2. Rated Voltage of XLPE Cable:0.6/1KV 6/10KV;8.7/15KV;12/20KV;18/20KV;21/35KV;6/35KV



3. Construction of XLPE Cable:

Conductor:Copper or Aluminum

Insulation:XLPE

Inner sheath:PVC or PE

Armoured:Galvanized steel tape,Galvanized steel wire

Outer Sheath:PVC or PE

NO. of cable cross: 1 core(Single core),2cores(Double cores),3cores, 4cores(4 equal-section-area cores OR 3 equal-section-area+1 small section area neutral core),5cores(5 3 equal-section-area cores+2 small area neutral cores OR 4 equal-section-area +1 small area neutral cores).We provide armored type and non-armored type for the cables stated above.

Also can do according to the customer's request.



4. Characters of XLPE Underground Armoured Power Cable:

a.Max  Long-time operating temperature of XLPE insulated cable is 90°C

b.Installing temperature of cable should not be less than 0°C

c.Max short-circuit temperature is not exceed 250°C,Not more than5 Sec.

d.Unable be laid without the limit of fall with enough mechanical pull,Single core cable can not be laid in iron tube or fixed by circled iron tools around cables
 5. Description & Application of XLPE Power Cable:

XLPE Underground Armoured Power Cable


Description
Application
 
 
Cu conductor(Al conductor)XLPE insulated PVC sheathed power cable
Laying indoors, in tunnel, fixed on the bracket, pipe and buried in the soil, the cable can not bear external mechanical forces.
 
Cu conductor(Al conductor)XLPE insulated PE sheathed power cable
 
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PVC sheathed power cable
For laying indoors, in tunnel, cable trench, or direct in ground, able to bear external mechanical forces, but unable to bear large pulling force.
 
Cu conductor(Al conductor)XLPE insulated double of steel-tape armored PE sheathed power cable
 
Cu conductor(Al conductor)XLPE insulated double of aluminium-tape armored PVC sheathed power cable
 
Cu conductor(Al conductor)XLPE insulated steel-wire armored PVC sheathed power cable
For laying indoors, in tunnel, cable trench, well or direct in ground, able to bear external mechanical forces and certain pulling force
 
Cu conductor(Al conductor)XLPE insulated steel-wire armored PE sheathed power cable
 
Cu conductor(Al conductor)XLPE insulated aluminium-wire armored PE sheathed power cable

XLPE insulation PVC sheath Power Cable

XLPE insulation PVC sheath Power Cable


1. Standard of XLPE Cable: According to GB12706( Equal to IEC60502).
Also can do by standard of ASTM,BS,DIN and AS/NZS or other standards as request.

2. Rated Voltage of XLPE insulation PVC sheath Power Cable: 6/10KV; 8.7/15KV; 12/20KV; 18/20KV; 21/35KV; 26/35KV

3. Construction of XLPE insulation PVC sheath Power Cable:

Conductor:Copper
Insulation: XLPE
Inner sheath: PVC
Armoured: None
Outer Sheath: PVC
NO. of cable cross: Multi cores
Armoring type for the cables is optional.
Also can do according to the customer's request.

4. Characters of XLPE insulation PVC sheath Power Cable:
a.Max Long-time operating temperature of XLPE insulated cable is 90°C
b.Installing temperature of cable should not be less than 0°C
c.Max short-circuit temperature is not exceed 250°C,Not more than5 Sec.
d.Unable be laid without the limit of fall with enough mechanical pull,
Single core cable can not be laid in iron tube or fixed by circled iron tools around cables

5. Advantages:
a. Excellent electric and mechanical characteristics
b. Best Resistance chemical corrosion and heat-ageing,environment stress and flame-retardant
c. Simple in structure,Convenient to use
d. Reduce costs

XLPE POWER CABLE   ,    CU/XLPE/SWA/PVC CABLE


Website:  www.xlpepowercable.com

XLPE Insulated Steel Wire Armored Power Cable

XLPE Insulated Steel Wire Armored Power Cable
 

APPLICATION:
XLPE INSULATED STEEL WIRE ARMORED POWER CABLE IS ADAPT TO THE WELL, WATER INSIDE AND FALL IN THE BAD SOIL, THE CABLE CAN BEAR THE EQUAL DINT OUTSIDE THE MACHINE WITH PULL THE DINT.
STANDARDS: IEC502,IEC332-3
CONDUCTOR: CU
INSULATION: XLPE (CROSS-LINKED POLYETHYLENE)
ARMORED: STEEL WIRE
SHEATH: PVC
SHEATH COLOR: BLACK OR GRAY
BENDING RADIUS:
SINGLE CORE: 20D ± 0.05, MULTI-CORE: 15D ±0.05
TEMPERATURE RATING:0℃ TO 90℃

XLPE Insulated Steel Wire Armored Power Cable , XLPE Power Cable 
6/10kV XLPE INSULATED STEEL WIRE ARMORED POWER CABLE
Nominal cross sectional area of conductor(mm2)
 Steel wire thickness(mm)
Approx, overall diameter(mm)
3×25
/
28.0
3×35
/
27.3
3×50
/
30.6
3×70
/
34.8
3×95
/
38.3
3×185
/
52.1
3×300
/
61.9

Website: www.xlpepowercable.com

Copper Core XLPE insulated Power Cables

Copper Core XLPE insulated Power Cable


The cable is manufactured according to IEC60502.1, IEC 60502.2, AS/NZS 1429, AS/NZS 5000.1, BS 5437, BS 6622/7835, VDE 0276, ASTM, ABNT etc . It is suitable to be installed in the power line with rated voltage from (U0/U)0.6/1kV to 19/33kV for power transmission.

Copper Core XLPE insulated Power Cable - Cable Specification

1. Scope
The cables included in this catalog are manufactured and tested in accordance with IEC 60502.2.Whereas,CHANGFENG can supply XLPE insulated cables or according to customer's specification.

2. Construction and material
1) Conductors
Annealed copper, Hard aluminum stranded wires, Compacted circular and segmental compacted circular
shall comply with IEC 60228 class 2.
2) Conductor Screen
This will be an extruded layer of semi-conducting crosslinkable compound applied under simultaneous triple extrusion process over the conductor along with the insulation and the insulation screen. The triple extrusion is a single high precision operation that eliminates the possibility of any contamination between the layers which could create irregularities in the electrical field.

3) Insulation
This will be an extruded layer of XLPE or TR-XLPE applied over conductor screen under triple extrusion process along with conductor screen and insulation screen. PVC may be used for 1.8/3KV and 3.6/6KV cables.

4) Insulation Screen
Non-metallic part:This will be a layer of semi-conducting crosslinkable compound which will be applied by triple extrusion process over the insulation.
Metallic part:Metallic layer shall consist of one or more tapes or a concentric layer of wires or a combination of wires and tapes.

5) Laying-Up
In case of three core cables, the three cores are laid up with non-hygroscopic fillers like polypropylene(PP) fillers at interstices and a binder tape is applied with an overlap. These binder tapes can be of  PVC or Non-woven fabric or foamed Polyethylene.

6) Inner Covering/Separation sheath
Inner covering may be extruded or lapped. When the underlying metallic layer and the armour are of different materials, they shall be separated by an extruded sheath of PVC or Polyethylene or LSF as applicable.

7) Armouring
Armour shall be as per IEC 60502-2 of the following types:
a)       Round Wire Armour
b)       Double Tape Armour
Armour material shall be Galvanized steel for three core cables and Non-magnetic steel or Aluminium for single core cables. Armour of other material as per IEC 60502-2 can be provided upon request.

8) Over Sheath
An extruded layer is applied over the armour in case of armoured cables and over laid up cores in case of unarmoured cables. Outer sheath material can be either PVC, PE, HDPE or MDPE. Caledonian medium voltage cables are normally supplied with red PVC over sheaths complying with IEC 60502. Other colors may be provided to suit a range of installation considerations such as the effect of UV radiations and differing soil compositions. Anti-termite formulations can also be supplied in addition to graphite-coated over sheaths where on-site testing of the sheath is required.

3. Phase Identification
For 3 core cables, Red, Yellow and Blue coloured strips shall be applied under the metallic screen thoughout the length of the cable for phase identification.
For single core cables no phase identification shall be provided.

The Rated Voltage, No of Core and Range of sectional Area

Rate Voltage(kv):0.6/1kV       1.8/3kV      3.6/6kV       6/10kV        8.7/15kV       12/20kV        18/30kV   21/35kV  


    Equivalent to : 0.6/1kV       1.9/3.3kV   3.8/6.6kV    6.35/11kV    8.7/15kV      12.7/22kV     19/33kV   21/35kV   


Copper Core XLPE insulated Power Cable

No. Of Core and Sectional Area(mm2) :
1 Core 1.5-800     25-800     25-1200     25-1200     35-1200     50-1200     50-1200     50-1200
2 Core 1.5-185     25-185
3 Core 1.5-400     25-400     25-400     25-400     35-400     50-400     50-400     50-400
4 Core 2.5-400     25-400
5 Core 2.5-400     25-400


Copper Core XLPE insulated Power Cable - Type, description and application
Type
Description
Applications
YJV/ YJLV
Cu or AL conductor XLPE insulated PVC sheathed power cables.
For laying indoors, in tunnels, in ducts. Able to bear extermal mechanical force but not large pulling forces. Single core cables are impermissible to be laid in magnetic ducts.
VV /VLV
Cu or AL conductor PVC insulated PVC sheathed power cables.
YJY /YJLY
Cu or AL conductor XLPE insulated PE sheathed power cables.
VJY/VLY
Cu or AL conductor XLPE insulated PE sheathed power cables.
YJV22/YJLV22
Cu or AL conductor XLPE insulated PVC sheathed internal steel tape armoured power cables.
For laying indoors, in tunnels, in ducts and underground. Able to bear extermal mechanical force but not large pulling forces, Impermissible to use single core cable in A.C circuit.
VV22/VLV22
Cu or AL conductor PVC insulated PVC sheathed internal steel tape armoured power cables.
YJY23/YJLY23
Cu or AL conductor XLPE insulated PE sheathed internal steel tape armoured power cables.
VY23/VLY23
Cu or AL conductor PVC insulated PE sheathed internal steel tape armoured power cables.
YJV32 /YJLV32
Cu or AL conductor XLPE insulated PVC sheathed internal steel wire armoured power cables.
For laying in areas along route with large difference of elevation, in shafts and in water, able to bear a corresponding pulling forces and external mechanical forces.
VV32/VLV32
Cu or AL conductor PVC insulated PVC sheathed internal steel wire armoured power cables.
YJY33/YJLY33
Cu or AL conductor XLPE insulated PE sheathed internal steel wire armoured power cables.
VY33/VLY33
Cu or AL conductor PVC insulated PE sheathed internal steel wire armoured power cables.
 Note: 1. 1kV flame reardent XLPE insulated power cable of category A,B and C as well as fire resistant XLPE insulated power cable can be manufactured complying with the requirements of national standard and IEC standard.
2. Single-core armoured cable: armored material for non-magnetic steel belt or steel wire.
Our certification
Our products meet standards of UL, GB, IEC, DIN, ASTM, JIS, NF, AS/NZS CSA GOST etc. As leading professional supplier in China, we have obtained ISO9001, ISO14001, CCC, API & UL certificates.

Copper Core XLPE insulated Power Cable


we are one of top electric cable manufacture in north of china,main product include xlpe power cable,armoured cable,swa cable,single core cable,2 3 4 core armoured cable.

XLPE Power Cable

XLPE Power Cable

1,Conductor: ALuminum,Copper
2,Insulation: XLPE
3,Jacket:PVC
4,Armored:Option

XLPE Power Cable
1.Application:
Power cables for power networks, underground, outdoors and in cable ducting.
2.Standards:
GB/T 12706,GB/T11017,GB/T 18380
3.Conductor:
Copper & Aluminum
5.Conductor screen:
Semi-conducting Layer
6.Insulation:
XLPE
7.Insulation Screen:
Semi-conducting Layer
8.Metallic Screen:
Individual and overall copper tape screen
9.Bedding:
PVC
10.Armoring:
Single Core: Aluminum Wire Armored (AWA)
Multicourse: Steel Wire Armored (SWA)

11.Sheath:
PVC
12.Color:
Red or Black
13.Voltage Rating:
6350/11000V
14.Temperature Rating:
0 to +70°C
15.Minimum Bending Radius:
Single Core: 15 x overall diameter
Three Core: 12 x overall diameter
(Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former)

XLPE Power Cable

>Not drop restriction on laying
>Stable & process performance
>Strong ability to adapt to the environment
>Short circuit (the longest duration of not more than 5s)
>The highest temperature of cable does not exceed 250 °C
>The maximum normal operating temperature of conductor 70°C
>Good flexibility, easy maintenance, installation, simple structure
>AC rated voltage 0.6/1kv,50 HZ for the fixed installation , transmission and distribution lines.
In cable laying, to ensure sufficient mechanical tension in the case of not drop restrictions, but the single core cable can’t be laid in the iron pipe, it’s also not permissible for using steel instrument around and fix the cable .During the cable laying ,its temperature is not less than zero,
11kV XLPE PVC Cable
Cable Type No. of Cores x Nominal Cross Sectional Area# x mm² Nominal Diameter Under Armour Nominal Diameter Over Armour Nominal Diameter Overall Nominal Weight Continuous Current Rating in Ground – Trefoil Continuous Current Rating in Ground – Flat
mm mm mm kg/Km Amps Amps
Copper 1 x 50 21.7 24.9 28.5 1200 220 230
Copper 1 x 70 23 26.2 30 1500 270 280
Copper 1 x 95 24.7 27.9 31.7 1600 320 335
Copper 1 x 120 26.7 29.9 33.9 2100 360 380
Copper 1 x 150 27.5 31.5 35.7 2500 410 430
Copper 1 x 185 29.3 33.3 37.5 2900 455 485
Copper 1 x 240 31.6 35.6 40 3600 520 560
Copper 1 x 300 34.6 38.6 43 4300 580 640
Copper 1 x 400 37 41 45.8 5200 650 730
Copper 1 x 500 40.5 45.5 50.5 6500 710 830
Copper 1 x 630 44.6 49.6 54.8 8000 760 940
Copper 1 x 800 48.8 53.8 59.2 9850 810 1060
Copper 1 x 1000 53.5 58.5 64.3 12100 860 1170
Copper 3 x 25 39 44 48.8 4300 140 140
Copper 3 x 35 41.6 46.6 51.6 4700 170 170
Copper 3 x 50 44.4 49.4 54.6 5300 210 210
Copper 3 x 70 48.1 53.1 58.5 6300 250 250
Copper 3 x 95 52 57 62.6 7300 300 300
Copper 3 x 120 55.6 60.6 66.6 8400 340 340
Copper 3 x 150 58.6 63.6 69.8 9600 380 380
Copper 3 x 185 62.7 67.7 74.1 11000 430 430
Copper 3 x 240 68.1 74.4 81.2 14000 500 500
Copper 3 x 300 73.5 79.8 87 16600 540 540
Copper 3 x 400 81.1 87.4 95 19500 600 600


website:  http://www.xlpepowercable.com

SWA Armoured XLPE Cable

SWA Armoured XLPE Cable


Keywords:

xlpe power cable,
xlpe armoured power cable,
SWA Armoured XLPE Cable,
steel wire armoured power cable,

Introduction:
The products can be produced according to our factory specification which is equivalent to the standard IEC60502. The factory can also design and manufacture special XLPE power cable according to the other standards required by the customers. They not only have excellent electric, mechanical properties, but also have powerful resistance against chemical corrosion, heataging and environmental stress. Their structures are simple. The permissible maximum operating temperature is 90C. It is convenient for using, and they can be laid with no restriction of different elevation.

SWA Armoured XLPE Cable - Application:
It is used to transmit and distribute power in power transmission and distribution system of 1kV. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.

SWA Armoured XLPE Cable - Using features:
1. Rated voltage: Uo/U:3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
2. No. of core: Single core or three cores.
3. The highest allowed operating temperature of conductor for long-term working is 90oC. In short-circuit (Max. long-term is no more than 5 seconds). The highest temperature for conductor is no more than 250oC.
4. D.C. resistance of the conductor complies with the stipulations of 3.6/6kV, 6/10kV(11kV), 12/20kV(24kV), 19/33kV, 26/35kV(35kV).
5. The environment temperature should be no lower than 0oC when lay. Otherwise it should be preheated.
6. The cable is laid without horizontal drop limit.
7. Working Frequency Voltage Test: 3.5Uo/5min without puncture.
8. Partial Discharge Test: The discharge volume should be no more than 10pC under 1.73Uo for the cable.

SWA Armoured XLPE Cable
 

XLPE Insualted PVC Sheathed Steel Wire Amoured High Voltage Cable with Copper or Aluminum Conductor.

Prief intruduce:
Voltage  Rate
3.6/6KV, 6/6KV, 6/10KV, 8.7/10KV, 8.7/15KV, 12/20KV, 18/20KV,
18/30KV, 21/35KV, 26/35KV
Cores
1C, 3C
Range of Nominal
cross section:
Single core:25 mm2 ~ 630 mm2
3 cores: 25 mm2 ~ 400 mm2
Application
It applies to the transmission and distribution lines with rated voltage
from 3.6/6KV to 26/35KV, to be laid directly in ground, outdoors, indoors
and in cable ducts.
Standard
IEC60502, BS6622, VDE0276, GB/T12706
Constructions
Conductor: Class 2 annealed copper strands
Core shield: semi-conducting compound + copper tape metallic screen
Insulation: XLPE
Sheath: PVC